Automatic burner control unit LME11.330C2 to EN298 for intermittent operation, suitable for single-stage operation, without actuator control.
Technical data:
1st safety time (TSA): 3s
Pre-purge time (t1): 30s
Pre-ignition time (t3): 2s
Post-ignition time (t3n): 2,5
Mains voltage: AC230 V -15%/+10%
Mains frequency: 50 ... 60 Hz ±6%
Power consumption: 12 VA
Temperature range: -20 ... +60°C
Air humidity: < 95% r.h.
Protection class: IP40 (ensure by installation)
Dimensions: approx. 91 x 62 x 62.5 (L x W x H in mm)
Weight: approx. 0.18 kg
Technical data:
1st safety time (TSA): 3s
Pre-purge time (t1): 30s
Pre-ignition time (t3): 2s
Post-ignition time (t3n): 2,5
Mains voltage: AC230 V -15%/+10%
Mains frequency: 50 ... 60 Hz ±6%
Power consumption: 12 VA
Temperature range: -20 ... +60°C
Air humidity: < 95% r.h.
Protection class: IP40 (ensure by installation)
Dimensions: approx. 91 x 62 x 62.5 (L x W x H in mm)
Weight: approx. 0.18 kg