Multiple control unit with thermoelectric ignition protection with restart interlock, modulating on-off thermostat, pressure regulator or alternatively flow regulator. A piezoelectric igniter can be installed on request. Available with flow control of the pilot burner output as well as minimum and maximum pressure setting (flow setting) of the main output. Gas outlet connection in series or from below. Supplied without cover, pilot gas fitting and ignition cable, please enquire if required. Inlet 1/2" - outlet 3/8" for single gas ovens 13° - 38° C. P max. 50 mbar, outlet pressure 15 - 30 mbar, temp. 0 -80°C.
Deutsch
English